Detail Information

Type: Body Fluids Processing Equipments Instrument Classification: Class II
Warranty: 2 Years After-sale Service: Online Technical Support
Product Name: Hemodialysis Machine Monitor: 15" Touch-screen Monitor
Power: 220 Volts AC, 50 Hz Material: All Wetted Parts In Stainless Steel
Pressure Monitoring: The Following Pressures Are Monitored Inlet Pressure Min: Min. 3 Bar At 1000 L/h To 3000 L/h Dynamic
Inlet Pressure Max: 6 Bar Static Storage Temperature: 5℃~40℃, At Relative Humidity<=80%
Keyboard: 4 Button Handling Port: SHANGHAI

Product Description

 

CE approved!! Double pump multifunctional Hemodialysis machine/ DIALYSIS machine HM02

 

CE  approved!! Double pump multifunctional Hemodialysis machine/ DIALYSIS machine HM02 for sale 0

 

 

 

 

Applications:

 

*Multifunctional hemodialysis machine is used to clear the toxin in the blood. It is also used for the patients with poisoning, renal failure, diabetes, kidney disease and uremia.

 

Features:

1.Whole disinfection for Re-Pipette
For you to change-the function of disinfection with Re-Pipette is up to the requirements of SOP.
 
2.Flexible and effective disinfection
Including the chemical disinfection and hot disinfection, the disinfection inlet is equipped with disinfection conductivity detector (L5) to check if the disinfection meets the standard and using correct disinfection fluid by itself.
 
3.Without "Dead" Cavity Design
The whole cavity and spare parts are simply and beautiful designed, and the conductivity is integration designed so as to reduce hemodialysis concentrated solution infectious rate caused by the bacteria, viruses in the fluid.
 
4.Unique function of Ultrafiltration – prevent the hypotension
This unit has the function of programmable UF and adjustable sodium dialysis, which is able to effectively prevent the complication such as hypotension and muscle cramp to reach the optimal UF goal during the whole process of HD.
 
5.Back-up Power
In case of power out, the machine will switch to spare power supply automatically, which can last for 30 minutes for operator resume the powder or end the treatment by pressing the bridging key to return the blood back to patient body.
 
Specific Parameter

Techinical Specification:
- Open system allowing the utilization of consumables from different suppliers
- 15" touch-screen monitor, rotatable, display of icons, words for quick and easy use
- Operating instructions shown on the high-resolution 15" TFT monitor
- Volumetric ultrafiltration control and sequential ultrafiltration
- Integrated status indicator in the monitor
- Fully automatic self-test prior to any start of dialysis automatic priming
- Heparin pump for syringes from 10 to 30 ml, programmable infusion (no infusion, profiled infusion, auto-bolus or continuous infusion)
-Bicarbonate powder cartridge holder: for dialysis treatments with cartridges for hygienic dialysis
-Blood leak and air bubble detector
-Continues on-lin Kt/V measurement without the need of any disposable supplies
-Automated temperature and pressure measurement
- Six individually programmable and/or preset profiles for
Dialysate temperature
-Sodium
-Ultra-filtration
-Bicarbonate
-Dialysate flow
-Heparin rates
-Dialysis flow rate adjustment from 300 to 800 ml/min in individual steps of 1 ml
-Pyrogene and endotoxin filter to produce ultrapure dialysis fluids
-One blood pump with adjustable settings
-Battery power supply in case of power breakdowns (15 minutes d'autonomie)
-Automated blood pressure measurement (ABPM), non-invasive by oscillometric method, various programmable cycles
-Biologic RR Comfort, automated blood pressure stabilisation based on blood pressure related ultrafiltration control without the need of any additional propriety disposable supplies Crit-Line interface connection allows the connection of the Crit-Line device to the Dialysis Machine. -Crit-Line is a fluid management access monitoring tool. It measures the absolute hematocrit in percent, assesses haemoglobin, measures continuous oxygen saturation and vascular access recirculation Patient disc and card reader: this option registers automatically the patient at the machine, activates automatically the set-up of all patient individual dialysis parameters and saves treatment data on the patient card
-Single-needle dialysis as SN click-clack (requires no specific blood tubing)
-Pressure sensor (PBE) to identify coagulation in dialysers prior to any transmembrane pressure (TMP) alarm
- Integrated timer on/off for automated disinfections/preparation procedures
- Programmable cleaning and disinfection modes, for chemical, heat or a combination of chemical/heat disinfection, programmable weekly disinfection table, validated heat-disinfection for citric acid 50% (bactericidal, fungicidal, tuberculocidal, virucidal, inactivation incl. HBV, HCB, HIV)
- Automated standby function to safe permeate, concentrates and energy in preparationmode
- Complies with EN 60601
- CE approved
- Power: 220 Volts AC, 50 Hz.
- Plug type: CEE 7/7
Optional:
- Same configuration as above but with double pump

Water Treatment System Two unit each Can Support Twenty Heomodilaysis Machines

2.1 Per-filtration system including:
-Back flush filter and pressure-reducing valve
-Booster pump
-Sand Filter System and / or
-CIR Filter System for remove of ferric, manganese, sulphur in clear drinking water
-Activated Carbon Filter System For rest dechlorination of drinking water
-Chlorine Filter for treatment of chlorinated portable water
-Double softener system
-Media rail panel:
- Aluminium channel with dead zone free permeate connections.
- All connectors are heat-disinfectable and resistant for hot water.
- Single place or double place connectors available for permeate, drain water and concentrate.
- The panel includes a centralized drain column system – which is covered by the same Aluminium cover as the main panel itself, it prevent smell and noise.
- Inside the panel there is an isolation to keep the Pe-Xa loop constantly heated up while a heat disinfection process is on-going.
- Upgrades of additional connectors and extensions are easily possible because of the compact design and the flexible components.
- Ultrafiltration and Heat-disinfection
- Ultrafiltration guarantees a reliable retention of bacteria and endotoxines. The heat-disinfection enfolded the whole permeate ring-main as well as the dialysis connection pipe inclusive the inlet sector.

Equipment / Specifications
Patented procedure of Ultrafiltration of permeate
High lifetime of the ultra-filter by cross-flow-operation
Water economy by concentrate recirculation of the ultra-filter to the reverse osmosis
3-step permeate pressure valve for fully automated filling of the tank at permeate oversupply
Micro controller processed
Integrated pressure pump
Compatible for reverse osmosis systems

Hygienic
- Complete V4A-tubing, inside surface refined with clamp connectors
- PVC-free assembly of the tubing

Performance data:
- Tank volume: 500 litres, usable water quantity ca. 480 litres
- Double walled stainless steel tank (1.4404) with Isolation
- Ultrafiltration membrane made of polyether sulphone

Retention:
-Bacteria retention > 5 log step (Factor 100.000)
-Endotoxin retention > 5 log step (Factor 100.000)
-Temperature at heat disinfection > 75°C

Mechanical connections:
- Permeate input, permeate reduction reverse osmosis, permeate ring-main feed, permeate return, 3 metres pressure tube DN 20, drain HT 50 (com. to ring feeding tube connector and ring return connector)
Electrical data:
- 400 V, 3~/N, 50-60 Hz, max. 14 kW
- Heater 12 kW, pressure pump max. 2 kW
- Dimensions / Weight (WxHxD): 790 x 1950 x 1450 mm / ca. 350 / 850 kg (tank empty / full)

Optional:
Water Protector
- Temperature sensor for measuring of temperature at the beginning of the ring
- Cutting unit for shut-off of the permeate supplying during the chemical disinfection of the reverse osmosis without opening the ring-ain.

Manufactured to MPG/MDD – System of group IIa

2.2 Central reverse osmosis unit
- All pipe work manufactured in stainless steel. Free of dead legs at the conduit and connectors which grants permeate of highest purity (purified water).
- Products graded in permeate capacity / extension class:
350 l/h, 700 l/h, 1050 l/h, 1400 l/h, 1750 l/h
- Permeate capacity each at 12°C water temperature

Upgradable by extension sets.
- For increased performances several systems can be connected in parallel.

Water inlet:
- Inlet pressure min.: min. 3 bar at 1000 l/h to 3000 l/h dynamic
- Inlet pressure max.: 6 bar static (pressure reducer in front of the system required)

Voltage:
- 230/400V 3-phase 50 Hz
- 230/400V 3-phase 60 Hz
- 115/200V 3-phase 60 Hz

- Power consumption electric: 3 kW

Used Guidelines, standards and regulations:
- Guideline of Council 93/42 EWG Medical Device Directive
- Medical electrical equipment – Part 1: General requirements for safety (IEC 601-1:1988 + A1:1991 + A2:1995)
- Safety requirements for electrical equipment for measurement, control, and laboratory use part 1: General requirements (IEC 61010-1:2001)

Temperature sensor:
- Monitored temperature at permeate for system protection.

Optional overflow valve:
-An additional overflow valve made of stainless steel provides over-temperature protection of the ringmain and dialysis machine.
- Pressure monitoring: The following pressures are monitored:
- Permeate pressure electronic
- Inlet pressure electronic and by pressure gauge
- Pump pressure by pressure gauge
- Conductivity measurement: Plug-in conductivity sensors monitored the following conductivities:
- Softened water
- Permeate
- Fine wire fuses: Protects the control and monitoring circuits against possible overload.
- Short regeneration time (approx. 25 minutes) (DVGW approved).
- 20" Pre-filter System for removal of medium and smaller particulate matter.
- Housing material: PP pressure resistant up to 8.6 bar
- Filter insert: 5 u m absolute cartridge
- Ball valve for soft water control and sampling.
- Frame and break tank manufactured in prickled stainless steel (AISI 304).

Pressure Pumps
Type:
-Grundfoss CRi 3-25 (50 Hz) / CRi 3-31 (60 Hz)
-Grundfoss CRi 3-17 (50 Hz) / CRi 3-21 (50 Hz)

Material:
- All wetted parts in stainless steel

Type of pump:
- Vertical, normal suction pump.
- With maintenance-free sliding seals.
- Connection by hygienic clamp-connectors.

Membrane housing
-Material: stainless steel AISI 316L. Matt pickled outside and inside. 4"membrane
-Membrane equipped with thin film polyamide membranes 4"
-DOW XLE-4040 – polyamide wounded – Extra Low Energy
-Retention rate of inorganic substances: > 98%
-Pipe work in stainless steel AISI 316L / AISI 316Ti. Matt pickled outside and inside.
-Ball valve in stainless steel with position permeate to ring main resp. permeate to drain for service requirements.

Main controller consisting of:
- Control board: Performs all control and monitoring functions. Self-checking on start-up
- Text display: Provides menu, guidance, displays for alarms, operating conditions and limit values.
- Keyboard: 4 button handling.
-Optional remote control controlling and monitoring from a central control room.

 