Electric Multi Parameter Vital Signs Monitor Class II

Minimum Order Quantity : 1PCS Price : $3,200.00 - $5,000.00/Units
Packaging Details : Carton Delivery Time : about 5 days
Payment Terms : T/T, Western Union,Payoneer Supply Ability : 5000 Unit/Units per Month South Africa Unavailable
Place of Origin: Hebei, China Brand Name: CONTEC
Certification: CE,ISO13485 Model Number: HMS9900

Detail Information

Power Source: Electric Warranty: 1 Year
After-sale Service: Repair And Replacement Material: Plastic
Shelf Life: 1years Quality Certification: No
Instrument Classification: Class II Safety Standard: None
Type: First-Aid Devices Product Name: Patient Monitor
Port: Beijing/Tianjin/Shenzhen/Shanghai
High Light:

Multi Parameter Vital Signs Monitor

,

parameter patient monitor

,

Vital Signs Monitor Class II

Product Description

Electric Multi Parameter Vital Signs Monitor Class II

 

Electric Multi Parameter Vital Signs Monitor Class II 0
Introduction
HMS9900 is a device with remote self-examination function, after verifying by entering account and password, user' ECG, SpO2, NIBP, TEMP, blood glucose, routine urine, lung function, height, weight, cholesterol and uric acid can be tested, and the examination report can be uploaded to Cloud Health platform, which ensures the health data can be real-time uploaded, achieves remote interaction of health service.
Application range: community service station, physical examination center, clinic, enterprise, health club, bank, apartment for the elderly and pharmacy, etc.

Functions
1)Self-examination
Integrated examination, self-service measurement
2)Multi-data collection
Standard parameters: ECG, NIBP, SpO2, temperature, weight, blood glucose, routine urine, lung function
3)Network mode
Wired, Wi-Fi, 3G
4)Login by multi-mode
Phone number, health card
5)*Cloud storage
Data measured can be uploaded to Cloud Health platform, safe and private to manage health archives, convenient to inquire anywhere anytime.
6)*Private health cloud service
Long-term storage, analysis and review for physiological trend data
7)*Health management service
Provide health instruction and consultation service by cloud experts.
8)Registration
Register by the phone number.
Note: the contents marked with “*” are provided by cloud terminal.

Performance
1)ECG(5-lead)
Lead: I, II, III, aVR, aVL, aVF, V
Waveform: 7-channel
HR range: 15~300bpm
Accuracy: ±1% or ±1bpm, whichever is greater
Resolution: 1bpm
Frequency response:
Method A: bandwidth 0.67Hz~40Hz, 0.05Hz~150Hz(diagnosis mode), (-3dB)upper limit: 110%(be equivalent to the output of inputting 5Hz sine wave)
Method B: 11.25~15mm
Calibrating voltage: 1mV±5%
Sensitivity: auto, 5mm/mV, 10mm/mV, 20mm/mV
Paper speed: 5mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s
Time constant: ≥3.2s
Noise: ≤30μV(p-v)
CMRR: ≥90dB, ≥105dB(filtering mode)
Baseline control and stability: baseline drift rate should be less than 10μV/s, drift with temperature changing should be less than 50μV/°C.
With the following functions: standard 12-lead, sync collection for 12-lead, sync recording, automatically providing test results, forewarning for abnormal ECG, lead-off alarm and remote transmission.
2)NIBP
Measure Method: Oscillometry
Working mode: single auto measurement
Measurement range:
Adult:
Systolic pressure: 30~270mmHg
Diastolic pressure: 10~220mmHg
Mean pressure: 20~235 mmHg
Resolution: 1 mmHg
Over-pressure protection:
Adult: 297±3 mmHg
Miximum mean deviation: ≤±5mmHg
Maximum standard deviation: ≤8mmHg
3)SpO2
Measurement range: 0%~100%
Resolution: 1%
Accuracy: 70%~100%, ±2%
Measurement mode: fingertip
4)TEMP
Measurement range: 34℃~43℃
Accuracy: ±0.2℃
Resolution: 0.1℃
5)Blood glucose
Sample: capillary whole blood
Measurement range: 2.7~27.8mmol/L
Accuracy deviation: ≤4.2mmol/L, ≤±0.83 mmol/L
 >4.2mmol/L, ≤±20%
Calibration curve: automatically select test curve by the correction code
Data transmission: test results can be transmitted
Test time: 25s
6)Routine urine
Test items: GLU, BIL, SG, PH, KET, BLD, PRO, URO, NIT, LEU, VC.
Test speed: ≥ 60 samples/hour
Repeatability: CV≤1%
Stability: CV≤1%
Test result: it is semi-quantitative or quantitative data, normal reference value can be provided.
Power On Self Test(POST): POST function, recognize and report the error, store and recall the test data after power failure
Data transmission: test results can be transmitted
7)Lung function
Volume range: 0~10L
Volume accuracy: ±3% or ±0.05L(whichever is greater)
Flow range: 1L/s~16L/s
Flow accuracy: ±10% or ±0.3L /s(whichever is greater)
Waveform: flow rate-volume chart, volume-time chart
Data transmission: test results can be transmitted
8)Weight
Measurement range: 5kg~200kg
Accuracy: ±0.1kg
Division: 0.1kg
Data transmission: test results can be transmitted

Accessories
1)Cuff for adult(22~32cm), NIBP extension tube
2)Infrared Body Thermometer
3)Blood glucose meter, USB cable, test strip(including lancet)
4)Urine Analyzer, test strip, power adapter(5V), USB cable
5)SPIROMETER, mouthpiece, USB cable
6)Power cord
7)User Manual

Physical characteristic
Dimension: 957mm(L) × 760mm(W) × 1400mm(H)
Weight: about 40kg

Optional configuration
ECG(12-lead), fetal heart, hemoglobin, uric acid, cholesterol, laser printer

 

Patient Monitor

 

 

Model Parameters Parameters(detail)

Screen size
(inch)

Touch
screen

Central 

Monitoring 

WIFI/
Cellular
Printer
PM50 2 NIBP/SPO2  2.4  N  N N  N
CMS5000 2 NIBP/SPO2  2.4  N  N N  N
CMS5000C 2 NIBP/SPO2  2.4  N  N N  Y
CMS5100 3 NIBP/SPO2/TEMP  2.8  N  N N  N
CMS6500 6 NIBP/SPO2/TEMP/ECG/RESP/PR  7  Y  Y Y  Y
CMS6000 6 NIBP/SPO2/TEMP/ECG/RESP/PR  8  N  Y Y  Y
CMS7000 6 NIBP/SPO2/TEMP/ECG/RESP/PR  12.1  N  Y Y  Y
CMS7000 PLUS 6 NIBP/SPO2/TEMP/ECG/RESP/PR  12.1  Y  Y Y  Y
CMS8000 6 NIBP/SPO2/TEMP/ECG/RESP/PR  12.1  N  Y Y  Y
CMS9000 6 NIBP/SPO2/TEMP/ECG/RESP/PR  12.1  N  Y Y  Y
CMS6800 6 NIBP/SPO2/TEMP/ECG/RESP/PR  8  N  Y Y  Y
CMS9200 6 NIBP/SPO2/TEMP/ECG/RESP/PR 15  N  Y Y  Y
CMS9200 PLUS 6 NIBP/SPO2/TEMP/ECG/RESP/PR  15  Y  Y Y  Y
HMS6500 9 NIBP/SPO2/TEMP/ECG/RESP/PR  7  Y  N Y  N
HMS7500 9 NIBP/SPO2/TEMP/ECG/RESP/PR  10.1  Y  N Y  N

For model CMS6000/6500/6800/7000/7000 PLUS/8000/9000/9200/9200 PLUS, optional functions are:

IBP, ETCO2, 12 LEAD ECG, BUILT-IN PRINTER, VGA OUTPUT, CO, MOVING BRACKET,HANGING BRACKET.

 